Introduction to the H3A
The H3A is an electronic eScore target with acoustic sensors. It supports both subsonic and supersonic ammunition and is designed for shooting distances of 100–300 metres, while also supporting use at other distances.

H3A target features
- 4 acoustic sensors, one in each corner of the target
- Wide range of target faces are available
- The guide pins make it easy to change the target face without readjusting the zero point.
- Supports subsonic projectiles such as .22LR at distances up to 100 m, and supersonic projectiles such as .223, .308, .30-06, 6.5 mm and 6 mm.
Technical specifications and dimensions
A |
1300 mm |
![]() |
B |
1300 mm |
|
C |
500 mm |
|
D |
300 mm |
|
E |
68 mm |
![]() |
F |
36 mm |
|
G |
92 mm |
|
H |
155 mm |
| Temperature range | −30 to +60 °C |
| Weight | ~ 28 kg |
| Power consumption | ~ 4.4W @ 24 VDC |
| Calibers | Subsonic and supersonic projectiles |
Exploded view and parts list
| Item | Part name | W5 part number |
| 1 |
The target → Target U5A - eScore → Target H3A - eScore |
13020313 13020177 |
| 3 | Main target rubber skin (2pcs pr target) | 97020540 |
| 6 |
Guide pins (4pcs pr target) → threaded centre → non threaded centre → headed, non threaded center |
97020728 97020850 97020845 |
| 7 | Front temperature shield |
Several versions available See table below |
| 8 | Foam sheet |
Several versions available See table below |
| 9 | Rear temperature shield | 13020103 |
| 10 | Target face |
Several versions available See table below |
| 11 | Fixation nut (8pcs pr target) | 97020729 |
| 14 | Male I/O cable |
Amphenol: 13020209 M23: 13020190 |
| 15 | Female I/O cable |
Amphenol: 13020210 M23: 13020191 |
| 16 | Horizontal rubber band |
97020895 (60 cm width) 97020547 (46 cm width) |
| 18 | Top cover | 97020527 - 130cm |
Front temperature shields available
Abbr. part name |
W5 part number |
Target configuration no. |
Image |
P30A |
13020133 |
#1 |
|
P40A |
13020104 |
#2 |
|
P50A |
13020106 |
#3 |
|
P60A |
13020243 |
#4 |
Available foam sheets
| Abbr. part name | W5 part number | Fits target configuration no. |
| FS 30x30/35x35 | 13020155 | #1 |
| FS 40x40/50x50 | 13020158 | #2 |
| FS 50x50/60x60 | 13020159 | #3 |
| FS 60x60/70x70 | 13020154 | #4 |
| FS 60x60/120x80 | 13020213 | #4 |
Target faces available
| Abbr. part name | W5 part number | Fits target configuration no. | Fits target scoring definition no. |
| R13'' | 13020081 | 1, 2, 3, 4 | 369 |
| R19'' | 13020082 | 3, 4 | 370 |
| R6.35'' | 13020130 | 1, 2, 3, 4 | 372 |
| 1/10-fig | 13020226 | 1, 2, 3, 4 | 155 |
| C20-fig | 13020227 | 1, 2, 3, 4 | 278 |
| C25-fig | 13020228 | 1, 2, 3, 4 | 350 |
| 1/8-fig | 13020229 | 2, 3, 4 | 348 |
| (10/30)-fig | 13020230 | 1, 2, 3, 4 | 353 |
| (30/10)-fig | 13020231 | 1, 2, 3, 4 | 277 |
| ⅓-fig | 13020232 | 3, 4 | 38 |
| R20 | 13020250 | 1, 2, 3, 4 | 7, 77, 169, 269 |
| R60 | 13020251 | 4 | 3, 6, 21, 196, 217, 288, 295 |
| R8'' | 13020277 | 1, 2, 3, 4 | 123, 378, 379, 384, 413 |
| R11 ¾'' | 13020278 | 1, 2, 3, 4 | 426 |
| ¼-fig | 13020280 | 2, 3, 4 | 39 |
| 1/4V-fig | 13020281 | 2, 3, 4 | 429 |
| C30-fig | 13020282 | 2, 3, 4 | 40 |
| 1/6-fig | 13020283 | 4 | 279 |
| S25H-fig | 13020284 | 4 with 13020213 | 351 |
| (13/40)-fig | 13020285 | 2, 3, 4 | 276 |
| (40/13)-fig | 13020286 | 2, 3, 4 | 352 |
| S25V-fig | 13020287 | 4 with 13020213 | 356 |
| Småen figure | 13020297 | 1, 2, 3, 4 | 113 |
| IPSC V2/A | 13020298 | (*Note 2) | 440 |
| R24 | 13020304 | 1, 2, 3, 4 | 1, 92 |
| R40 | 13020305 | 2, 3, 4 | 2, 4, 170, 399 |
| B45-fig | 13020319 | 2, 3, 4 | 354 |
| C40-fig | 13020320 | 2, 3, 4 | 357 |
| Circle-fig | 13020321 | 1, 2, 3, 4 | 79, 349 |
| Tønne figure | 13020322 | 1, 2, 3, 4 | 164 |
| Blank | 13020387 | 1, 2, 3, 4 | All (*Note1) |
| C15-fig | 13020388 | 1, 2, 3, 4 | 156 |
| P-Fig | 13020397 | 1, 2, 3, 4 | 453 |
| D-Fig | 13020398 | 1, 2, 3, 4 | 452 |
| Fiskebeck | 13020416 | 4 with 13020213 | 447 |
| Mini P-fig | 13020417 | 1, 2, 3, 4 | 450 |
| Mini 1/9-fig | 13020418 | 1, 2, 3, 4 | 448 |
| Dråpe figure | 13020419 | 1, 2, 3, 4 | 449 |
| 1/9-fig | 13020420 | 1, 2, 3, 4 | 451 |
| Reindeer | 13020345 | 1, 2, 3, 4 | 64 |
| Running (Norwegian siam) moose | 97060013 |
1, 2, 3, 4 (Note 3) |
30 |
Note1: This all-white target face can be fitted with the customer's choice of target figures.
Note2: This target face is black. White spot is intended, by adding white contrast sheet (W5 part no: 140205409).
Note 3: Requires a target extender.
Target Rubbers
|
Rubber skins at the front and rear of the frame form a soundproof measuring chamber together with the rubber band. The rubber skins have a Ø35/Ø25 cm opening in the centre, reducing wear that can affect scoring accuracy. Consider enlarging the opening to Ø55 cm when shooting at distances of 300 m or more. |
|
|
A horizontal rubber band keeps the measuring chamber soundproof and simplifies maintenance. It must always remain in contact with the skins and cover their openings. See the maintenance and rubber band movement section below. |
Dismantling
See exploded view and parts list in accordion above.
The target must be partly dismantled for maintenance. Pull upwards to remove the top cover, which is attached with hook-and-loop fasteners. Remove the guide pin nuts to take off the remaining parts.
H3A target maintenance
Moving or replacing the rubber band and foam sheet
Projectiles wear the target rubber as they pass through it. Over time, this can let noise into the soundproof measuring chamber.
Wear normally occurs in the centre of the target. A rubber band and foam sheet cover the centre, simplifying maintenance and reducing costs.
The rubber band must cover the opening in the skin, whether factory-cut or cut later. Move it sideways to bring unworn rubber into the centre. Replace the foam sheet when moving the rubber band.
Maintenance requirements depend on the calibre, projectile type, shooting distance and shot grouping. The following intervals are recommended as a guide for this target model:
| Shooting distance | Ammunition | Rubber band movement interval |
| 100 m | Small-bore ammunition (.22LR, subsonic projectiles) used alongside full-bore ammunition. | After 500 rounds |
| 100 m | Full-bore ammunition with supersonic projectiles only. | After 1000 rounds |
| 200 m | Full-bore ammunition only. | After 1500 rounds |
| 300 m | Full-bore ammunition only. | After 3000 rounds |
These intervals assume standard full metal jacket projectiles, except .22LR, and relatively tight groups. Wider groups may allow longer intervals. Hunting ammunition may require more frequent maintenance.
Keep the rubber band joint at the rear of the target. Avoid positioning it in the centre until the final usable section of the band is reached.
If the band is not excessively worn, move it sideways by approximately half the diameter of the opening in the front skin. This brings unworn rubber into the centre. On a new target, this is approximately 20 cm (8 inches).
Replace the band after it has been moved through half a turn. Remove the upper guide pins before fitting the new band. Soapy water in a spray bottle can reduce friction and simplify replacement.
VIDEO
Inspecting and replacing temperature shields
The temperature shields help maintain an even temperature inside the target, including in sunlight. Projectiles wear them, particularly the centre of the rear shield.
| The rear temperature shield starts to bulge after a few hundred shots. | ![]() |
| The rear shield has a removable section to prevent the measuring chamber from collapsing. | ![]() |
| Remove this section when the rear shield starts to bulge. Refit it with the side containing the removable section facing the rubber skin. | ![]() |
Replace the rear shield when the opening reaches 40 cm (15 inches) in diameter.
Sunlight and other environmental exposure also degrade the shields. Replace them when the material no longer holds together or they lose their shape.
Repairing ricochet damage to the rubber skin
Sideways or deformed projectiles can create large holes in the rubber skin.
If the holes are in the centre of the band, move it to prevent scoring errors.
Patch holes in the skin outside the band using spray adhesive and adhesive tape, or fast-curing superglue and a rubber patch.
Inspecting the rubber skin
Replace the rubber skins in the following situations:
| 1. |
Excessive wear and numerous shot holes can reduce scoring accuracy, particularly around the opening in the front skin. The problem becomes worse when the rubber no longer holds together and large flaps hang loose. A worn edge can be trimmed with scissors to enlarge the opening. The rubber band must still cover the entire opening with a generous 3–4 cm margin. |
| 2. | The rubber skin loses tensile strength as it ages. Wind can then cause the measuring chamber between the skins to collapse. Loosening, tensioning and refitting the skin can provide a temporary solution. |
| 3. | The skin can eventually crack. Cracks may become holes and compromise the soundproof measuring chamber. |
Inspecting and cleaning sensors
The lower sensors behind the service hatch are well out to the sides and are rarely exposed to dust and particles. Cleaning them with a soft brush when replacing the skins is normally sufficient.
Inspect the sensors regularly if stray projectiles have hit the inside of the frame. Remove any splinters or wood chips resting on the sensors.
Inspecting the target face
Projectiles wear the target face. Replace it when the figure is no longer clear to the shooter. Remove the retaining nuts at the front and the top cover before changing the face.
Inspecting the service hatch
The hatch at the bottom provides access to the target electronics and lower sensors. Open and close it using the white rubber straps at the bottom of the target.
Check that the hatch, hinges and straps are intact and that the hatch closes fully. There must be no gaps allowing sound into the measuring chamber. Keep it closed and secured, except during servicing or inspection inside the target.
The rubber straps weaken over time. Replace them when they lose tensile strength.
Inspecting sensor wires
Sensor wires run along the left and right sides of the frame. Inspect the outermost 10 mm for stray shots that may have damaged them. See the next section for repairs. Wires can easily be removed from the channels for inspection or replacement.
A severed or short-circuited sensor wire generates an eScore warning and the target will probably stop registering shots. Partial damage may only cause problems once exposed to moisture. Inspect wires regularly if shots have passed close to or through the cable channels.
Target repairs and spare parts
Repairs
Stray shots risk hitting the upper acoustic sensors, upper temperature sensor or their wiring. This section explains how to repair in these cases.
Repairing sensor wiring
All upper sensor cables run along the outer edge of the target frame to simplify repairs. If a bullet or ricochet cuts a cable, the target electronics detect the sensor fault and report warnings to the scoring system. LEDs on the circuit board also indicate sensor status. The board is accessible behind the service panel at the bottom of the target.

Crimp connectors can be used for a temporary cable repair. For a permanent repair, replace the cable or solder the joint and seal it with heat-shrink tubing. Remember to join the uninsulated conductor as well.
Replacing sensors
In some cases it might be easier or necessary to replace the entire sensor with wiring harness.
Connect the sensor wires to their numbered terminal blocks as shown in the tables below:
| Terminal number | Attached sensor |
| A1 | Upper right acoustic sensor |
| A2 | Lower right acoustic sensor |
| A3 | Lower-left acoustic sensor |
| A4 | Upper left acoustic sensor |
| T1 | Lower temperature sensor |
| T2 | Upper temperature sensor |
The terminal blocks are on the left side of the board, shown in green in the image above. A1 is at the bottom left, followed upwards by A2, A3 and A4. Each block has connection points numbered 1, 2 and 3.
Connect the A1–A4 sensor cables as follows:
| Wire | Connection point |
| Red | 1 |
| Black | 2 |
| Cable screen / Ground | 3 |
Connect the T2 sensor cable as follows:
| Wire | Connection point |
| White | 1 |
| Black | 2 |
| Cable screen / Ground | 3 |
Connect the T1 sensor cable as follows:
| Wire | Connection point |
| Red | 1 |
| Green | 2 |
| Yellow | 3 |
Replacing the upper acoustic sensors
To replace an upper sensor, detach a corner of the rubber skin from the frame. Access from the front is recommended. The acoustic sensors are taped to aluminium brackets screwed to the frame.
Upper-right acoustic sensor on its aluminium bracket. The upper-right temperature sensor is also visible.
Use the same screws and screw holes when replacing the sensor.
The temperature sensor should extend only 2–3 cm into the target frame.
Replacing I/O cables
I/O cables are supplied in fixed lengths. The male and female cables connect to IO1 and IO2 on the right side of the circuit board. Their ground wires are secured to the metal mounting plate for the target electronics.

When ordering I/O cables, choose the connector series used by the rest of the system. See the exploded view and parts list at the start of this manual for part numbers.
I/O cables are secured to the frame with cable clamps and adhesive tape. Follow the original cable routing when fitting replacements. Have cable ties and cloth tape ready before starting.
Form a loop in each I/O cable inside the target for strain relief. Shape and secure the loop with cable clips so that it cannot touch nearby sensors. The images below show examples from different target models:
![]() |
![]() |
I/O cables should extend approximately 14 cm below the target frame.

Spare parts
| W5 part number | Description | Image |
| 97020851-240cm | Acoustic sensor with mounting plate | |
| 97020522-220cm | Upper temperature sensor cable | |
| 97020842 | Lower temperature sensor | |
| 13020209-85cm | Male I/O cable (Amphenol) | |
| 13020210-85cm | Female I/O cable (Amphenol) | |
| 13020190 | Male I/O cable (M23) | |
| 13020191 | Female I/O cable (M23) | |
| 97020517 | Target electronics mounting bracket | |
| 97020812 | Target electronics cover | |
| 97020728 | Guide pin (threaded centre) | |
| 97020850 | Guide pin (non threaded centre) | |
| 97020845 | Guide pin (headed, non threaded centre) | |
| 97020729 | Guide pin nut | |
| 1502007 | Hinge | |
| 1507012 | Rubber strap | |
| 1507013 | Cover fastening button | |
| 97020532 | Assembly plate | |
| 97020722 | Rubber gasket (underneath assembly plate) | |
| 1302004 | Repair tape | |
| 1302007 | Spray glue |
| 13280000-H3A | Target electronics | |
| 97020147 | Aluminium strip | |
| 97020527-130cm | Target top cover | |
| 97020582 | Target service hatch | |
Protecting the H3A target
Protecting the target against stray projectiles and ricochets
The target's critical electronic components are located at the bottom, behind the service panel. Protect this area with a protective wall or plates to reduce maintenance costs and improve durability. Target stands with protective plates are available on request.
See YouTube video for recommendations on how to install the targets.

Protection from ricochets and shrapnel
Fragments from bullet catchers can cut or short-circuit cables. Route cables between targets, antennas, batteries and other equipment carefully to minimise this risk. Cover steel bullet catchers with rubber or another suitable energy-absorbing material to reduce escaping ricochets and fragments.