Stray shots risk hitting the upper acoustic sensors, upper temperature sensor or their wiring. This section explains how to repair in these cases.
Repairing sensor wiring
All upper sensor cables run along the outer edge of the target frame to simplify repairs. If a bullet or ricochet cuts a cable, the target electronics detect the sensor fault and report warnings to the scoring system. LEDs on the circuit board also indicate sensor status. The board is accessible behind the service panel at the bottom of the target.

Crimp connectors can be used for a temporary cable repair. For a permanent repair, replace the cable or solder the joint and seal it with heat-shrink tubing. Remember to join the uninsulated conductor as well.
Replacing sensors
In some cases it might be easier or necessary to replace the entire sensor with wiring harness.
Connect the sensor wires to their numbered terminal blocks as shown in the tables below:
| Terminal number | Attached sensor |
| A1 | Upper right acoustic sensor |
| A2 | Lower right acoustic sensor |
| A3 | Lower-left acoustic sensor |
| A4 | Upper left acoustic sensor |
| T1 | Lower temperature sensor |
| T2 | Upper temperature sensor |
The terminal blocks are on the left side of the board, shown in green in the image above. A1 is at the bottom left, followed upwards by A2, A3 and A4. Each block has connection points numbered 1, 2 and 3.
Connect the A1–A4 sensor cables as follows:
| Wire | Connection point |
| Red | 1 |
| Black | 2 |
| Cable screen / Ground | 3 |
Connect the T2 sensor cable as follows:
| Wire | Connection point |
| White | 1 |
| Black | 2 |
| Cable screen / Ground | 3 |
Connect the T1 sensor cable as follows:
| Wire | Connection point |
| Red | 1 |
| Green | 2 |
| Yellow | 3 |
Replacing the upper acoustic sensors
To replace an upper sensor, detach a corner of the rubber skin from the frame. Access from the front is recommended. The acoustic sensors are taped to aluminium brackets screwed to the frame.
Upper-right acoustic sensor on its aluminium bracket. The upper-right temperature sensor is also visible.
Use the same screws and screw holes when replacing the sensor.
The temperature sensor should extend only 2–3 cm into the target frame.
Replacing I/O cables
I/O cables are supplied in fixed lengths. The male and female cables connect to IO1 and IO2 on the right side of the circuit board. Their ground wires are secured to the metal mounting plate for the target electronics.

When ordering I/O cables, choose the connector series used by the rest of the system. See the exploded view and parts list at the start of this manual for part numbers.
I/O cables are secured to the frame with cable clamps and adhesive tape. Follow the original cable routing when fitting replacements. Have cable ties and cloth tape ready before starting.
Form a loop in each I/O cable inside the target for strain relief. Shape and secure the loop with cable clips so that it cannot touch nearby sensors. The images below show examples from different target models:
![]() |
![]() |
I/O cables should extend approximately 14 cm below the target frame.


