The target has front and rear temperature shields to reduce temperature differences in the measuring chamber. Direct sunlight on the rubber can cause large temperature changes and uneven temperatures within the chamber.
The shields reduce these changes and protect the rubber from UV radiation, which can accelerate material degradation.
Over time, shots wear through the centre of the shields. The foam inserts in the centre of the front shield take most of this wear and are inexpensive to replace. Replace them whenever the rubber bands are rotated. The shields themselves have a long service life. Replace the rear shield when the shot-out area becomes too large.
The rubber-coated foam inserts also help seal the measuring chamber, improving scoring accuracy and reducing rubber band wear.
Remove debris and dirt from the opening in the temperature shield before fitting a new foam insert.