Power supply cabinet 24V – with or without eHub

W5 · INFRASTRUCTURE

Power and networking.

The 24 V cabinet supplies power to targets and antennas and connects the equipment to the eScore network. It contains a power supply, network switches, fuses and surge protection, and is available with or without eHub and with Amphenol or M23 connectors.

This guide covers all four variants. The product image shows the M23 variant with eHub.

W5 24 V cabinet, shown with eHub and M23 connectors

24 V DC

Supplies power to targets and antennas. The connectors carry both 24 V DC and Ethernet in the same cable.

With or without eHub

With eHub, the system includes the server for the eScore interface and network services. The variant without eHub provides power and network distribution.

Amphenol / M23

Two connector variants with the same function. Choose cables that match the connectors on the cabinet and the equipment being connected.

The cabinet's role in the system

The 24 V cabinet supplies 24 V DC to targets and antennas. The network switches connect this equipment to the rest of the eScore network. Both power and Ethernet are carried through the cabinet’s equipment connectors.

Each eScore system can have no more than one eHub. Use no more than one cabinet with eHub in the same system. Additional cabinets are used without eHub to provide power and network distribution.

Variants with eHub also include the server that makes the eScore interface available in a web browser. Variants without eHub provide local power and network connections within the system.

The images below show the cabinet variant with eHub and M23 connectors.

24 V cabinet with eHub, viewed at an angle from the side

 

Studio image of the 24 V cabinet with eHub and the door open

 

Find your variant

The part number identifies whether it includes eHub, and which connector type it is supplied with.

W5 part no Variant Connectors
13360010 Without eHub Amphenol
13360010-A035 Without eHub M23
13360012 With eHub Amphenol
13360012-A035 With eHub M23

Amphenol or M23

Both connector types are available on variants with and without eHub. Use the part number on the product label to select cables with the correct connectors.

Amphenol

13360010
13360012

Target cable with Amphenol connectors from the product catalogue

M23

13360010-A035
13360012-A035

Target cable with M23 connectors from the product catalogue

Getting to know the cabinet

The image shows 13360012-A035, the variant with eHub and M23 connectors. Use the numbers in the image and table to identify the main components. eHub is marked with number 6 and is included in variants with eHub.

Annotated component overview: 1 power supply, 2 surge protection, 3 network switches, 4 fuses, 5 M23 connectors and 6 eHub

The image shows 13360012-A035, with eHub and M23 connectors. Numbers 1–6 refer to the explanations in the table below. Open the overview without annotations.

1. Power supply Converts a mains supply of 110–230 V AC to 24 V DC for the equipment connected to the cabinet.
2. Surge protection Helps protect the equipment against short-duration voltage surges. The cabinet has type 2 surge protection with status windows. Technical ratings are listed under “Protection, fuses and inspection”.
3. Network switches Connect targets, antennas and other connected equipment within the eScore network. Variants with eHub include an internal network connection to eHub.
4. Fuses Three time-delay fuses rated at 5 A / 250 V, size 6.3 × 32 mm. The fuses protect the cabinet’s circuits. Circuit assignments follow the labels and wiring diagram.
5. Power and network connectors The connectors carry both 24 V DC and Ethernet and are used to connect targets and antennas. They are Amphenol or M23, depending on the variant. The M23 cabinet shown has three connectors.
6. eHub The server that makes the eScore interface available in a web browser. eHub also acts as the DHCP server, automatically assigning IP addresses on the eScore network, and as the internet gateway. Included in 13360012 and 13360012-A035.

Connectors and connections

The cabinet is supplied with Amphenol connectors or M23 connectors. The M23 variant in the studio images has three M23 connections and one power inlet. Use cables that match the connector variant, and follow the connection labels and wiring diagram supplied with the cabinet.

Close-up of surge protection modules, switches and three M23 connectors

The three M23 connectors are grouped below the surge protection modules.

Detail of the power inlet below the three M23 connectors

The power inlet is below the M23 connectors.

Power input Power inlet for 110–230 V AC. Use the power cable supplied with the cabinet and follow its labelling.
Target and antenna connectors Connectors carrying 24 V DC and Ethernet for targets and antennas. Use Amphenol or M23 connectors as appropriate for the cabinet variant. Check the connector and cable before connecting. Align the plug correctly and secure it without forcing it.
Cable entry Route cables through the entry at the bottom. Ensure they have clearance and strain relief, and cannot be trapped when the door closes.

 

Positioning and installation

  • Wall or pole mounting. Secure the cabinet using mounting hardware appropriate for the installation location and the cabinet's mounting points.
  • Ground clearance. Mount the cabinet well above ground level, particularly outdoors. The bottom has a brush seal. If snow or water builds up from the ground and reaches the bottom of the cabinet, water can easily enter. Choose a mounting height suited to local snow conditions and possible standing water, and keep the area beneath the cabinet clear.
  • Space for access. Leave enough space to open the door, connect cables and read the labels.
  • Provide cable strain relief. Route cables so that their weight and movement do not pull on the connectors.
  • Keep the door and seal in good condition. Check that the sealing surface is clean and that no cables are trapped.
Inside of the cabinet door with seal and wiring diagram

 

Underside of the 24 V cabinet shown

 

Working inside the cabinet
The cabinet contains mains voltage. Electrical servicing, changes to internal wiring and work on the power supply, fuses and protection devices must be carried out by qualified personnel. Contact W5 if servicing is required.

Start-up and daily use

  1. Check the cabinet and cables. Look for visible damage, moisture and loose connections before connecting power.
  2. Connect power. Use the cabinet's power inlet and the cable supplied with it. Allow the network equipment and any installed eHub to start.
  3. Check connected equipment. Check that equipment powered by the cabinet has started and is available in the system.

On systems with eHub you can check connected devices in eStatus. Start-up and connections for the eHub itself are described in the next section.

For variants with eHub

eHub is installed alongside the power supply and network switches. It makes the eScore interface available in a web browser to devices on the system’s network. It also acts as the DHCP server, automatically assigning IP addresses on the eScore network. As the internet gateway, it connects the eScore network to an internet-connected network through its WAN port.

Network connections on the eHub

The network ports on the eHub are labelled LAN and WAN. LAN connects to the local eScore network. WAN is used for an optional connection to an upstream network or the internet, according to the system configuration.

Close-up of eHub showing the physical LAN and WAN port labels

Follow the physical port labels on the eHub when making connections.

Keep the internal wiring as supplied. If you need to change the network configuration, follow the guide Getting started with eHub or contact W5.

After start-up, connect your computer, tablet or phone to the system's network and open the interface for the relevant eHub. Check connected devices in eStatus before using the system.

Further setup of the eHub

Device registration, user settings and eStatus are covered in Getting started with eHub.

Protection, fuses and inspection

Inspect the cabinet regularly, particularly before using the system after an extended break. Look for damaged cables and connectors, moisture inside the cabinet, and wear on the seal and cable entry.

The surge protection modules have status windows. On the modules shown in the images, green indicates that protection is working, while red indicates that the protection module needs replacing. Contact W5 if a status window has turned red.

Surge protection ratings

Protection type Type 2
Nominal discharge current (In) 20 kA (8/20 µs)
Maximum discharge current (Imax) 40 kA (8/20 µs)
Voltage protection level (Up) < 2.0 kV

The cabinet has three time-delay fuses rated at 5 A / 250 V, size 6.3 × 32 mm. If a fuse fails, investigate the cause before returning the system to service. Replace it with the same current rating, time-delay characteristic and size, following the wiring diagram. Inspection and replacement must be carried out by qualified personnel.

Basic troubleshooting

The entire system has no power Check the external power supply and ensure the power cable is properly connected. If the fault persists, contact W5 to have the cabinet checked.
One connected device is unavailable Check the device's cable and connector, and look for error messages in eStatus. Tell support which connection and device are affected.
eHub interface does not open Check that your device is connected to the correct network and that you are using the address for the relevant eHub. Follow the start-up guide for further checks.
Red status window on surge protection module Contact W5 for inspection and replacement of the protection module.
Moisture, overheating or visible damage Stop using the cabinet and disconnect power if it is safe to do so. Contact W5 before using the cabinet again.

Product overview

Base product 24 V cabinet with power supply and network switching
Without eHub 13360010 · Amphenol
13360010-A035 · M23
With eHub 13360012 · Amphenol
13360012-A035 · M23
System voltage 24 V DC
Connections Amphenol or M23 depending on the variant, plus a power inlet. The M23 variant shown has three M23 connections.
Mains supply 110–230 V AC
Fuses 3 time-delay fuses · 5 A / 250 V · 6.3 × 32 mm
eHub Included in 13360012 and 13360012-A035
Protection Surge protection and fuses
Cabinet product label showing part number 13360012-A035 and serial number

 

Documentation and assistance

The wiring diagram is inside the door. Use the diagram and labels supplied with your specific cabinet.

Close-up of the wiring diagram inside the cabinet door

Wiring diagram in the cabinet shown. Use the documentation supplied with your cabinet.

Have the part number and serial number ready when contacting W5. Photos of the product label, relevant connector and any status indicators help us provide the right assistance.

Contact W5 support